- wide-band level measuring
- selective level meter
with selectible bandwidth
- searching for signals on
a higher level than set
- measuring and viewing
signal spectrum
|
|
|
|
|
Level meter LM98 and LM98-A
|
The level meter LM98 (LM98-A) is a modern
measuring device. It accelerates and simplifies the
operations connected with the measuring and choosing of
appropriate lines in frequency range up to 2,1 Mhz.
The
LM98 (LM98-A) level meter is a portable battery device designed
mainly for choosing and measuring of access network dual
cables. It can carry out wide-band measuring in the range
up to 2,1 Mhz or selective measurings in the range up to
1,2 Mhz.
Features:
- wide-band level measuring
- selective level meter with selectible bandwidth
- searching for signals on a higher level than set
- measuring and viewing signal spectrum
- loop resistance measuring
- bleeder resistance measuring with disconnected
loop
- line capacity measuring
- memory for storing the most frequently used
measurings
- saving of measuring results
- possibility of saving boundary values for quick
"suitable/not suitable" evaluation
- automatic control of the programmable SG98 generator on the
tested line
- possibility of automatic calibrating with SG98
- PC cooperation
LM98 (LM98-A) can measure line frequency parameters, d-c line
resistance, bleeder resistance and the line capacity.
LM98 (LM98-A) can measure the total level of unweighted voltage
and search the frequency spectrum for the most powerful
sources of unweighted voltage.
In the autonomous mode the LM98 (LM98-A) is controlled from the
foiled keyboard. The measuring results are shown on the
four-line display.
The device is very user-friendly.
SG98 (SG98c) can be connected to a PC with a
galvanically isolated output. The PC can be used to enter
measuring orders and the PC screen to display the
measuring results.
LM98 (LM98-A) features ten memories for programming measurement
sequence including boundary values. It suffices to launch
the appropriate programme to proceed.
Measuring results can be stored in the memory or
printed out as a result report.
Remote signal generator SG98
controlled on the measured line can be used when
measuring frequency characteristics
| BASIC
TECHNICAL PARAMETERS |
LM98 |
LM98-A |
| feeding voltage |
44 pc NiCd accumulator type AA or 220V for
mains feeding |
| operating time |
min. 2 hours with 950mAh NiCd accumulators |
| loop resistance measuring |
5Ohm up to 2000Ohm |
| bleeder resistance measuring |
10kOhm up to 1MOhm |
| line capacity measuring |
10nF up to 2µF |
| frequency range:wide-band measuring |
50Hz up to 2,1MHz |
| selective measuring |
50Hz up to 1,2MHz |
| minimal bandwidth: band up to 4kHz |
20Hz |
10Hz |
| minimal bandwidth: band up to 40kHz |
200Hz |
100Hz |
| minimal bandwidth: band up to 1,2MHz |
800Hz |
320Hz |
| measured levels |
-90dB to +12dB/dBm |
| resolution |
0,1dB |
| measured quantities |
dB, dBm, dBm0, mV |
| result evaluation |
RMS |
| input |
symmetrical 3 pole
non-symmetrical BNC |
| input impendace |
>10kOhm, 600Ohm, 135Ohm or 150Ohm, 75Ohm |
| display |
digital, on a connected PC |
| memory |
0 to 9 for most frequently used
measurings, saving of measuring
results 0 to 9 |
| size |
app. 120x250x45 mm |
|